TYLOSE MHF 10015 P4

TYLOSE MHF 10015 P4

TYLOSE MHF 10015 P4

CAS number: 9032-42-2

Tylose MH 10015 P4 is a water-soluble, non-ionic, modified methyl hydroxyethyl cellulose powder with standard etherification.
Tylose MH 10015 P4 provides fast consistency development, very high sag resistance and water demand, moderate water retention and influence on cement hydration, and high heat stability.
Tylose MH 10015 P4 is ideal for use in cement tile adhesives.

Product form : Mixture
Product name : Tylose MHF 10015 P4
Product code : MHEC_M_2

Recommended uses of Tylose MH 10015 P4:
-Rheological Additive
-Special applications
-Coating material
-Additive for mortar

Physical state : Solid
Appearance : Powder.
Colour : whitish
Odour : odourless
Odour threshold : No data available
pH : 6 – 8 10g/l
Relative evaporation rate (butylacetate=1) : Not specifically applicable
Melting point / Freezing point : Melting point: Not specifically applicable
Freezing point: Not specifically applicable
Boiling point : Not specifically applicable
Flash point : Not specifically applicable

Auto-ignition temperature : > 170 °C
Flammability (solid, gas) : No data available
Vapour pressure : Vapour pressure: Not specifically applicable
Vapour pressure at 50 °C: Not specifically applicable
Relative density : Relative vapour density at 20 °C: Not specifically applicable
Density : Density: 1.1 – 1.5 g/cm³ 20 °C
Relative density: Not specifically applicable
Solubility : Water: > 10 g/l @ 20°C
Log Pow : < 0

Viscosity, kinematic : Not specifically applicable
Viscosity, dynamic : Not specifically applicable
Explosive properties : Product is not explosive. Dust may form explosive mixture in air.
Explosive limits : No data available
Minimum ignition energy : > 10 mJ
Fat solubility : No data available
Conbustion class : 5
Smoldering temperature : >450 °C
pmax : 10 bar
Dust explosion category : ST1
KSt : < 200 bar*m/s
Ignition temperature : > 400 °C

TYLOSE MHF 10015 P4 has thickening, binding, dispersing, film-forming and suspending properties.
When the pH of TYLOSE MHF 10015 P4 aqueous solution is between 2 and 12, the viscosity is stable.
If TYLOSE MHF 10015 P4 exceeds this range, acidic or alkaline oxidative degradation occurs and viscosity decreases.

The viscosity of TYLOSE MHF 10015 P4 aqueous solution decreases as the temperature increases and the viscosity can be recovered as the temperature drops to the original temperature.
TYLOSE MHF 10015 P4 If there is no high salt concentration, no gel or precipitate will form when the solution is heated to the boiling point; TYLOSE MHF 10015 P4 is therefore very resistant to temperature.

TYLOSE MHF 10015 P4 aqueous solution is a nonionic system and can be used in other water soluble polymers, surfactants, salts, etc. can be found with.
For this reason, TYLOSE MHF 10015 P4 is widely used in the daily chemical industry.

Reactivity : The product is non-reactive under normal conditions of use, storage and transport.
Chemical stability : Stable under normal conditions.
Possibility of hazardous reactions : No dangerous reactions known under normal conditions of use.
Conditions to avoid : No decomposition if stored normally.
Incompatible materials : Strong oxidizing agent.

First-aid measures after inhalation : Remove person to fresh air and keep comfortable for breathing. Call a doctor.
First-aid measures after skin contact : Wash skin with plenty of water.
First-aid measures after eye contact : Rinse immediately with plenty of water, also under the eyelids.  Consult an ophthalmologist if irritation persists.
First-aid measures after ingestion : Rinse mouth. If symptoms persist, call a physician.

Tylose MHEC (methyl hydroxyethyl cellulose/Tylose MH-grades) are water soluble, nonionic cellulose ethers, which are offered as free flowing powder or in granular form.
Tylose MHEC may contain further additives which for example control the dissolution behavior or the thickening power.

Hand protection : Not required for normal conditions of use.
Choosing the proper glove is a decision that depends not only on the type of material, but also on other quality features, which differ for each manufacturer.
Please follow the instructions related to the permeability and the penetration time provided by the manufacturer
Eye protection : Not required for normal conditions of use
Skin and body protection : Wear suitable protective clothing

Tylose MB grades:
Tylose MB 15009 P2
Tylose MB 60000 P2

Tylose MH grades:
Tylose MH 50 G4
Tylose MH 200 YP2
Tylose MH 300 P2
Tylose MH 2000 YP2
Tylose MH 4000 KG4
Tylose MH 6000 YG8
Tylose MH 6000 YP4
Tylose MH 6002 P4
Tylose MH 10000 KG4
Tylose MH 10007 P4
Tylose MH 15000 YP4
Tylose MH 15002 P6
Tylose MH 15018 P4
Tylose MH 20006 P4
Tylose MH 20009 P2
Tylose MH 30000 YG8
Tylose MH 30000 YP4
Tylose MH 30026 P4
Tylose MH 60000 P6
Tylose MH 60001 P4
Tylose MH 60001 P6
Tylose MH 60004 P6
Tylose MH 60009 P4
Tylose MH 60010 P4
Tylose MH 100001 P6
Tylose MHBS 60000 YP4
Tylose MH 300003 P6

Tylose MHE grades:
Tylose MHE 60000 YP4

Tylose MHF grades:
Tylose MHF 10015 P4
Tylose MHF 10016 P4
Tylose MHF 20007 P4
Tylose MHF 20010 P4
Tylose MHF 60028 P6
Tylose MHF 150013 P6

Tylose MHS grades:
Tylose MHS 10012 P6
Tylose MHS 30024 P4
Tylose MHS 30027 P6
Tylose MHS 60000 YP4
Tylose MHS 100005 P3
Tylose MHS 100006 P3
Tylose MHS 150003 P4
Tylose MHS 150012 P4
Tylose MHS 300000 P4

Special grades:
Tylose CER 406001
Tylose E 510024
Tylose E 514016

Inquiry