NIPACIDE CI 15

NIPACIDE CI 15

NIPACIDE CI 15

Nipacide CI 15.
Chemical name: Chlor-methyl and methyl isothiazolinone

Nipacide CI 15 is an in-can biocide based on CMIT/MIT.
Nipacide CI 15 is a water based biocide, developed for the complete in-can protection of water based products including water based / Latex/PVA adhesives, PVA / acrylic polymer emulsions, water based decorative paints, printing inks, metal working fluids and construction admixtures.

Nipacide CI is effective against a wide range of microorganisms including gram positive and gram negative bacteria, yeast and fungi. Thermal and pH stability for Nipacide CI is a critical consideration and it should not be used for products with pH >8.5 or production temperatures of >40 °C.

Benefits
formaldehyde-free
bactericide
fungicide
pH stable 4-9
temperature stable up to 40° C
FDA approved for various applications

Description;
Nipacide CI 15 is water based, low toxicity biocide developed for the complete in-can protection of water based products. Nipacide CI 15 is effective against a wide range of microorganisms including gram positive and gram negative bacteria, yeast and fungi. Microorganisms grow at a rapid rate and without use of the correct biocide, numbers can increase dramatically.
Example of the numbers of bacteria able to grow in products if left unpreserved
• Time = 0 mins 1
• Time = 40 mins 4
• Time = 3 hrs 1024
• Time = 5 hrs 16,384
• Time = 7 hrs 1,048,576
• Time = 10 hrs 107,000,000,000
Time = 24 hrs 236,000,000,000,000,000,000,000
In-Can degradation in paints, polymer and adhesives as a result of bacterial and fungal contamination, can result in:
• Loss of viscosity
• Gassing
• Discoloration
• Bad odors
• Product splitting
• Loss of adhesion
• Production clean down and production down time
• Loss of profit

Applications;
Nipacide CI 15 is recommended for preservation of a wide range of applications including water based /Latex/PVA adhesives, PVA / Acrylic polymer emulsions, water based decorative paints, printing inks, metal working fluids and construction admixtures. Nipacide CI15 is effective against a wide range of common spoilage organisms. Thermal and pH stability for Nipacide CI15 is a critical consideration and it should not be use for products with pH >8.5 or production temperatures of >40 C.

Use level;
Nipacide CI 15 should be evaluated in finished products at levels between 0.1% and 0.3%. Please note, however, that the use of Nipacide CI 15 above 0.1% requires R43 (causes sensitization by skin contact) hazard labeling. If labeling is an issues it is recommended you consider an alternative Clariant biocide, either CMIT/MIT free or a CMIT/MIT combination biocide eg Nipacide CFX 4 or Nipacide IB
Microbiological data;
Nipacide CI 15 has a broad spectrum of activity which is demonstrated by the following MIC data.

MIC Levels Organism MIC (ppm)
Bacteria
Pseudomonas aeruginosa 400
Pseudomonas putida 250
Proteus vulgaris 900
Escherichia coli 700
Staphylococcus aureus 1000
Fungi
Aspergillus niger 150
Penicillium mineoluteum 150
Fusarium solani 100
Geotrichum candidum 300
Yeast
Candida albicans 50

STANDARD FIVE CHALLENGE TEST METHOD: Bacterial Challenge Test.
Samples Tested: PVA based adhesive
INOCULUM
The mixed Inoculum of bacteria used is as follows: –
Bacteria:
Pseudomonas aeruginosa
Alcaligenes faecalis
Proteus vulgaris
Escherichia coli
Standard scoring system
Product
Biocide
Level (%)
Week 1
Week 2
Week 3
Week 4
Week 5
PVA based adhesive
Unpreserved

3
3
3
3
3
PVA based adhesive
Nipacide CI15
0.15
0
0
0
2
2
PVA based adhesive
Nipacide CI15
0.20
0
0
0
0
0
PVA based adhesive
Nipacide BIT20
0.20
0
0
0
0
0
INOCULUM
The mixed Inoculum of fungi and yeast used is as follows : –
Fungi:
Fusarium solani
Geotrichum candidum
Aspergillus terreus
Yeast
Rhodotorula rubra
Saccharomyces cerevisiae
STANDARD FIVE CHALLENGE TEST METHOD: Fungal Challenge Test.
Samples Tested: PVA based adhesive
Standard scoring system
Product
Biocide
Level (%)
Week 1
Week 2
Week 3
Week 4
Week 5
PVA based adhesive
None

0
2
3
3
3
PVA based adhesive
Nipacide CI15
0.15
0
0
0
0
2
PVA based adhesive
Nipacide CI15
0.20
0
0
0
0
0
PVA based adhesive
Nipacide BIT20
0.20
0
0
0
1
1
Key: 0 – Complete Kill 2 – 102 – 104 Organisms/ml
1 – <102 Organisms /ml 3 – >104 Organisms/ml

Chemical compatibility;
Nipacide CI15 is compatible with most raw materials used in the manufacture of industrial products. Nipacide CI15 compatibility should always be checked and evaluated before use.

Clariant Technical Service;
Clariant technical service is available to assist customers in the determination of the optimum use level of biocide required to fully protect their product. A dedicated team of microbiologists are on hand at all times to assist customers with technical enquiries relating to product protection. Full microbiological efficacy testing is available.

AVAILABLE MICROBIOLOGICAL TESTING
• In can challenge.
• Dry film
• Chemical analysis
• Identification
• Disinfectant testing
• Microbiological audits

Regulations and approvals;
FDA21 CFR 175.105 Indirect food additives: Adhesive and components of coatings- Adhesives
FDA21 CFR 176.170 Indirect food additives: Paper and paperboard components-Components of paperboard in contact with aqueous and fatty foods
FDA21 CFR 176.180 Indirect food additives: Paper and paperboard components-Components of paper and paperboard in contact with dry food.
FDA 21 CFR.300 Indirect food additives: Paper and paperboard components-Slimicides.
BFR Rec X1V Preservative for Polymer emulsions in food contact application
BFR Rec XXXV1 Preservative for Paper and Board
EPA Approval. EPA registration number 49403-25
WGK Classification 2: water polluting

Biocide for the painting coating and polymers and printing ink and adhesive and pigment
Composition:  Aqueous solution of 5-Chlor-methylisothiazolin-3-one and 2-Methylisothiazolin-3-one

Product properties 1
Appearance (20°C)
Colour
Melting point
Liquid
greenish
approx.0 ℃
Active 1%-2.5%
Boiling point
Density at 20°C
approx.100℃
1.06 g/cm3
pH 2-4
Viscosity dynamic 20mPa.s (20℃)
Profile

Nipacide CI15 HS is water based, low toxicity biocide developed for the complete in-can protection of water based products.
Nipacide CI15 MV is effective against a wide range of microorganisms including gram positive and gram negative bacteria, yeast and fungi.
Microorganisms grow at a rapid rate and without use of the correct biocide, numbers can increase dramatically.

Application
Nipacide CI15 HS is recommended for preservation of a wide range of applications including water based /Latex/PVA adhesives, PVA / Acrylic polymer emulsions, water based decorative paints, printing inks, metal working fluids and construction admixtures.
Nipacide CI15 HS is effective against a wide range of common spoilage organisms.

Thermal and pH stability
for Nipacide CI15 HS is a critical consideration and it should not be use for products with pH >9 or production temperatures of >40 C.

Use level
Nipacide CI15 HS should be evaluated in finished products at levels between 0.1% and 0.3%.

Please note, however, that the use of Nipacide CI15 HS above 0.1% requires R43 (causes sensitization by skin contact) hazard labeling.
If labeling is an issue it is recommended you consider an alternative Clariant biocide, either CMIT/MIT free or a CMIT/MIT combination biocide eg

Chemical compatibility
Nipacide CI15 HS is compatile with most raw materials used in manufacture of industrial products, Nipacide CI15 HS compatibility should aways be checked and evaluated before use.

Clariant Technical Service
Clariant technical service is available to assist customers in the determination of the optimum use level of biocide required to fully protect their product.
A dedicated team of microbiologists are on hand at all times to assist customers with technical enquiries relating to product protection.
Full microbiological efficacy testing is available.

Safety
Please see Material Safety Data Sheet before handling the material.

Nipacide CI 15 is a low toxicity biocide specifically developed for the complete microbiological protection of water based products against bacterial and fungal spoilage in the wet state, particularly where it is to be used at high ambient temperatures.
It is a water based clear, yellow liquid.
Nipacide CI 15 is recommended for a wide range of applications including adhesives, polymer emulsions, fountain solutions, MWF and paint where protection against fungi and bacteria is required in the wet state.

METALWORKING FLUID PRESERVATION
Nipacide CI 15 microbiocide is recommended for the control of bacteria and fungi in soluble and emulsifiable type aqueous metalworking fluids.

For the maintenance of a nonfouled system, use Nipacide CI 15 microbiocide at 32 fluid ouncesNper 1000 gallons of emulsion (2 Ibs.) every 4 weeks or 3-154 fluid ounces per 1000 gallons emulsion (2-10 Ibs.) every 8-12 weeks.
For a noticeably fouled system use an initial dose of 64-154 fluid ounces per 1000 gallons emulsion (4-10 Ibs.) to be followed by subsequent maintenance dosages depending upon the treatment interval noted above.
A higher dosage range and/or increased fi-equency of treatment may be required depending upon rate of dilution of the preservative with makeup fluid the nature and severity of contamination, level of control required, filtration effectiveness, system design, etc.

The preservative should be dispensed into the use-dilution of the metalworking fluid using a metering pump and uniformly dispersed throughout the system.

METAL CLEANING FLUID PRESERVATION
Nipacide CI 15 microbiocide is recommended as a preservative for use in the manufacture and use of alkaline acid, and emulsion based metal cleaning fluids typically used in electroplating, phosphatizing, galvanizing and general metal cleaning operations.

For addition to a metal cleaning concentrate, add Nipacide CI 15 microbiocide at a level to ensure that the final use-dilution fluid will contain 425 to 1,675 ppm product (6.25 to 25 ppm active isothiazolones).

For direct addition to a fouled system, add 54-214 fl. oz. (3.6-14.1 Ibs.) of Nipacide LX microbiocide to each 1,000 gallons of use dilution metal cleaning fluid every 3-4 weeks to provide 425-1,675 ppm product (6.25-25 ppm active isothiazolones).

A higher dosage range and/or increased frequency of treatment may be required depending upon rate of preservative with the make up fluid, the nature and severity of contamination, level required, filtration effectiveness, system design, etc. . ,

The preservative should be dispensed into the use-dilution metal cleaning fluid using a metering pump and uniformly dispersed throughout the system

WATER-BASED HYDRAULIC FLUID PRESERVATION
Nipacide CI IS microbiocide is recommended as a preservative for use in the manufacture and use of high water-based hydraulic fluids and invert emulsion hydraulic fluids typically prepared by emulsifying 40% by volume water in 60% by volume of mineral oil using an oil soluble emulsifying agent.

For the maintenance of non-fouled systems in the mining, primary steel, motor vehicle production, machinery production, construction industry, etc. use Nipacide CI 15 microbiocide at 110-135 fluid ounces (7.2 – 8.8Ibs.) per 1,000 gallons fluid every eight (8) weeks.
For a noticeably fouled system use an initial dose of 135-235 fluid ounces (8.8-15.4 Ibs.) per 1,000 gallons liquid to be followed by subsequent maintenance dosage.
A higher dosage range and increased frequency of treatment may be required depending upon rate of dilution of the preservative with make-up fluid, the nature and severity of contamination, level of control required, filtration effectiveness, system design, etc.

The preservative should be dispensed into the use-dilution of the hydraulic fluid using a metering pump and uniformly dispersed throughout the system.

COMMERCIAL PHOTOPROCESSING SYSTEM PRESERVATION
Nipacide CI 15 microbiocide is recommended to preveilt slime formation or accumulation in filters and ion exchange resin tanks of commercial photoprocessing systems.

For the maintenance of a non-fouled system Use Nipacide Cl 15 microbiocide at 32-64 fluid ounces (2.1 lbs. to 4.2Ibs.) per 1,000 gallons of water in the system once weekly, or as needed to maintain control of slime. For a noticeably fouled system, use an initial dose of 64-154 fluid ounces (4.2 Ibs. to 10.1 Ibs.) per 1,000 gallons water to be followed by subsequent maintenance dosage.
A higher dosage range and/or increase frequency of treatment may be required depending upon rate of dilution of preservative with makeup fluid, the nature and severity of contamination, level of control required, filtration effectiveness, system design, etc.

The preservative should be dispensed into the final rinse or used water collection tank.

DISPERSED PIGMENT PRESERVATION
Nipacide CI 15 microbiocide is recommended as an in-container preservative for the control of bacteria and fungi in the manufacture and storage of dispersed pigments such as kaolin clay, montmorillite clay, titanium dioxide, calcium carbonate, calcium sulfate, barium sulfate, magnesium silicate, and kieselguhr used in paint and paper productions.
Add 0.43-1.65 Ibs. ofNipacide CI IS microbiocide (195-750 g) to each 1,000 lbs. (453 Kg) of fluid to provide 425 to 1,675 ppm product (6.25 to 25 ppm active isothiazolones).

ADHESIVE AND TACKIFIER PRESERVATION
Nipacide CI 15 microbiocide is recommended as an in-container preservative for the control of bacteria and fungi in water soluble and water dispersed adhesives such as animal gllle~, vegetable glues, natural rubber latices, polyvinyl acetate, styrene-butadiene, and acrylic latice;. Nipacide
CI 15 microbiocide is recommended as a preservative for tackifiers derived from hydrocarbon resins.
Add 0.43-1.65 Ibs. ofNipacide CI 15 microbiocide (I 95-750 g) to each 1,000 Ib3 of fluid to provide 425 to 1,675 ppm product (6.25 to 25 ppm active isothiazolones).

BUILDING MATERIAL PRESERVATION
Nipacide CI 15 microbiocide is recommended as an in-container preservative for the control or bacteria and fungi in building materials such as mastics, caulks, joint cements, spackling, and grouting.
Add 0.43-1.65 Ibs. of Nipacide CI 15 microbiocide (195-750 g) to each 1,000 Ibs. (453 Kg) of fluid to provide 425 to 1,675 ppm product (6.25 to 25 ppm active isothiazolones).

POLYMER LATEX PRESERVA nON
Nipacide C1 IS microbiocide is recommended for the control of bacteria and fungi in the manufacture and storage of synthetic and natural polymer latices including: acrylic; styrenelbutadiene; carboxylated styrenelbutadiene; ethylene/vinyl acetate; and biopolymers intended for industrial use, such as xanthum gum, gum arabic, guar gum, protein derived polymers, starches, and casein derived polymers.

Add 0.43 – 3.3 Ibs. ofNipacide CI 15 microbiocide (195g-I.5 Kg) to each 1,000 lbs. (453 Kg) of emulsion to provide 425 to 3,350 ppm product (6.25 to 50 ppm active isothiazolones).

NOTE: To insure uniform mixing, add Nipacide CI 15 microbiocide to latex or solutions slowly with agitation.
The actual concentrations required will depend upon such factors as the specific substance to be treated, frequency of repeated microbial contamination expected, and level of protection required.
Nipacide CI 15 microbiocide weight 8.4 pounds per gallon.

STORAGE AND DISPOSAL
PROHIBITIONS
This product is corrosive to mild steel. Do not store or transport in unlined metal containers.
Do not contaminate food or feed by storage, disposal, or cleaning of equipment.

PESTICIDE DISPOSAL
Pesticide wastes are acutely hazardous. Improper disposal of excess pesticide or rinsate is a violation of Federal law. If these wastes cannot be disposed of by use according to label
instructions, contact your State Pesticide or Environmental Control Agency, or the Hazardous Waste representative at the nearest EPA Regional Office for guidance.

CONTAINER DISPOSAL
METAL CONTAINERS: Triple rinse (or equivalent). Then offer for recycling or reconditioning, or puncture and dispose of in a sanitary landfill, or by other procedures approved by state and local authorities.

Inquiry